Terminal C-L cut-in at temperature rise. Terminal L-H of auxiliary switch cut-out when the shaft turned to OFF point. Terminal C-L can be cut-out at OFF point, and can be forced ON at ON point. The ON temperature is constant at any position from Warm to Cold, the OFF temperature is adjustable. This behavior assure an automatic defrost function.

The WD-R series with an internal bellows heating resistance connected to C-L, is able to be used at cross-ambient in a refrigerator.

Constant cut-in temp, range: +2~+8°C

Available OFF temp, range: -36—4°C

Adjustable temp, range: Max.l9°C

Differential: Min.8°C

bouton download pdf bouton download pdf

Refrigerators.

 


 

EWK

With a high current capability switch of SPST or SPDT. There is a narrow differential and a forced OFF function. This kind of thermostats can be used in direct current (DC) with inductive loads.

WK-B and WK-C series with bottom outlet terminals are available.

Thermostats with a fix operating temperature(without a shaft) for air conditioner defrosting are also availabe.

Available temp, range: -35~+40°C

Adjustable temp, range: Max.20°C

Differential: Min.2°C

bouton download pdf

img1

img2

img3

Room air conditioners, Freezers, Automobile air conditioners.


EWP

Terminal C-L Cut-in at temperature rise. With SPST or SPOT, and an additional auxiliary switch. There are forced OFF and/or PD points. Type WP-T with two-spring mechanism is a wide differential range.

Available temperature range: -36~+15°C

Adjusting temperature range Max.25°C

Differential: WP(5~14°C) 5-25 °C WP-T (10-25 °C)

bouton download pdf

img1

img2

img3

Refrigerating/freezing devices, Automobile air conditioeing


Terminal 3-4 closes at temperature rise

In general type KP is classified into 2 basic versions:

Version A: KP with standard switching differential

Version B: KP with wide switching differential

Rating at 250 V 50 Hz

3-4: 6(6)A

img1

img2

img3

Operating range: -40 to+40°C

Adjustment range: Vers ion A: 4 to 30K; Version B: 5 to 15K.

Switching differential: Version A: 3 to 14K; Version B: 10to25K.

Capillary type: Shape A (standard); Shape B (on request)

Refrigerating/freezing devices Automotive air conditioning


ekd series

Temperature control with S.P.S.T. switchand auxiliary switch for off position. Automatic defrost function by constant cut-in value

Terminal 3-4 closes at temperature rise

Terminal 3-6 opens in OFF position

Rating At 250 V 50 Hz

3-4: 6(6)A

3-6: 6(6)A

bouton download pdf

img1

Control shown in position COLD according to standard type, other dial shaft positions on request.

img2

img3

Operating range: -32 to +6°C

Adjustment range: 4 to 18K.

Constant cut-in value: +2 to +8K.

Capillary type: Shape A (standard); Shape B (on request)

Refrigerators


ekd series

Temperature control with S.P.S.T. switch and signal switch.

Terminal 3-4 closes at temperature rise

Terminal 3-6 closes when warning temperature has been reached

Rating At 250 V 50 Hz

3-4: 6(6)A

3-6: 0.1A

bouton download pdf

img1

Control shown in position COLD according to standard type, other dial shaft positions on request.

img2

img3

Operating range: -40 to +40°C

Adjustment range: 4 to 30K

Switching differential: 3 to 14K

Signal differential: 4 to 7K

Capillary type: Shape A (standard); Shape B (on request)

Freezers


ekd series

Constant cut-in thermostats for explosive area.

This is a special designed type with SPST switch plus an aux switch. It is an "n" type apparatus in accordance with the standard IEC79-15. It can prevent the possible explosion when the switch body is located in the explosive gas mixed air. Ex approval of China was obtained and VDE Ex test was past.

Maybe with an internal bellows heating resistance connected to C-L terminal to enable to be used at cross ambient in a refrigerator.

bouton download pdf

img1

Control shown in position COLD according to standard type, other dial shaft positions on request.

img2

img3

Constant cut-in temp, range: +2~+8°C

Arailable OFF temp. Range: -36—4°C

Adjustable temp, range: Max. 19°C

Differential: Min. 6°C

Refrigerators.